This site is under construction - get in touch if you want to know more

SurgicalOpNotes .co.uk

capLeft

capRight

boxTopLeft

Lorem

boxTopRight

Follow us on Twitter:

boxBottomLeft

boxBottomRight

 

OPERATION NOTE:

 Open Reduction & Internal Fixation Lateral Malleolus
(*=delete as appropriate)
Date of operation:

                        Patient name:      

                        Hospital number:

                        Date of Birth:       

Consultant   

Surgeon:                                                       Supervision:    Independent/Unscrubbed/Scrubbed*
Grade:          

Assistant:     
Grade:           

Anaesthetist:
Grade:           

Indication: Weber B fracture (AO 44-B1)

Background:    Patient consented, understanding the risks of  bleeding, infection, nerve damage, venous thrombo-embolism, non union, malunion, prominent metalwork, further surgery, complex regional pain syndrome, anaesthetic and need for further procedure (eg removal of metalwork).

Setup:              WHO safety checklist performed .Prepped with Betadine/Chlorhexidine* and draped

Anaesthetic:     Block / GA*

Antibiotics:       At induction mg_

Equipment:      Tourniquet:                         Tourniquet pressure: mmHg      Tourniquet time:mins

        Inflated after

        Image intensifier:

Position:           

Approach:         Direct lateral

                    Dissection down to bone, with care to avoid injury to deep peroneal nerve

Findings:           Fibular fracture at the level of the syndesmosis

Procedure:        Fracture identified, haematoma and any interposing periosteum cleared out. Fracture site refreshed.

        Fracture reduced and held with bone reduction clamp

        Standard small fragment (3.5mm) x    mm lag screw applied as per AO technique with hole drilled perpendicular to the fracture line, proximal segment drilled to nominal screw diameter (gliding hole) and distal to core screw diameter (2.5mm) and countersink drilled for screw head.

        The far cortex was/was not* tapped with a 3.5mm tap through protection sleeve.

        Fracture well reduced and held - blood extruded from fracture site with reduction.

         hole contoured 1/3 Tubular plate applied with good bicortical hold above and below the fracture.

        Washout.

        Haemostasis.

        Stable fixation confirmed with image intensifier and stress test with no talar tilt or shift. Final check x-ray images saved/printed*

Closure:           Deep tissue: vicryl, deep dermal vicryl 2-0 to deep and for skin. Jelonet

        Backslab at 90degrees flexion/Wool & Crepe*

        LA infiltrated at wound:

Post-op:            Routine obs. VTE prophylaxis. NWB with crutches. Home when safe.

        Follow-up with GP/in clinic in two weeks for wound review and removal of sutures.

        Follow-up in clinic in six weeks with removal of and x-ray on arrival.

QR Code         

Signed: ______________________

Generated with www.surgicalopnotes.co.uk

Scan the QR code above to see more

footerCapLeft

[Home] [About] [Trauma] [Elbow] [Hip] [Ankle] [Elective] [Contact Us] [FAQ]

footerCapRight